Kodelistebeskrivelse

GERDA - GEofysisk Relationel DAtabase

Kodeliste for PCGerda feltet Key i SkyDatList-tabellen:

CODE Identification of the code (SHORT_TEXT) Further description of the code (LONG_TEXT)
 
900 DBDT_CHN_NOISEON boolean, 0 (false) means that the slope filters
evaluates the data quality bases on the slope of
the curve (1st order derivative), 1 (true) means that
the slope filters uses the second order derivative of the curve.
910 DBDT_CHN_SLOPEFILTERS2ND boolean, 0 (false) means that the slope filters
evaluates the data quality bases on the slope of the curve (1st order derivative), 1 (true) means that the slope filters uses the second order derivative of the curve.
1000 DBDT_BIN_SPACING Sounding Bin Spacing [s]
1001 DBDT_CUR_TIME_DIST Current Time Distance [s]
1100 DBDT_CAPSIGN_FILTERON Cap Sign Filter
1101 DBDT_CAPSIGN_FROMTIME Cap Sign from time [s]
1102 DBDT_CAPSIGN_NOISELEVEL Cap Sign noise level (ms)[v/m2]
1103 DBDT_CAPSIGN_NOISESLOPE Cap Sign noise slope
1104 DBDT_CAPSIGN_BACKSTEP Cap Sign back step
1200 DBDT_CAPSLOPE_FILTERON Cap Slope Filter
1201 DBDT_CAPSLOPE_FROMTIME Cap Slope from time [s]
1202 DBDT_CAPSLOPE_NOISELEVEL Cap Slope noise level (ms)[v/m2]
1203 DBDT_CAPSLOPE_NOISESLOPE Cap Slope noise slope
1204 DBDT_CAPSLOPE_SLOPEMIN Cap Slope min slope
1205 DBDT_CAPSLOPE_SLOPEMAX Cap Slope max slope
1206 DBDT_CAPSLOPE_BACKSTEP Cap Slope back step
1300 DBDT_RAWSIGN_FILTERON Raw Sign Filter
1301 DBDT_RAWSIGN_FROMTIME Raw Sign from time [s]
1302 DBDT_RAWSIGN_BACKSTEP Raw Sign back step
1400 DBDT_RAWSLOPE_FILTERON Raw Slope Filter
1401 DBDT_RAWSLOPE_FROMTIME Raw Slope from time [s]
1402 DBDT_RAWSLOPE_MINSLOPE Raw Slope min slope
1403 DBDT_RAWSLOPE_MAXSLOPE Raw Slope max slope
1404 DBDT_RAWSLOPE_BACKSTEP Raw Slope back step
1500 DBDT_AVESIGN_FILTERON Ave Sign Filter
1501 DBDT_AVESIGN_FROMTIME Ave Sign from time [s]
1502 DBDT_AVESIGN_BACKSTEP Ave Sign back step
1600 DBDT_AVESLOPE_FILTERON Ave Slope Filter
1601 DBDT_AVESLOPE_FROMTIME Ave Slope from time [s]
1602 DBDT_AVESLOPE_MINSLOPE Ave Slope min slope
1603 DBDT_AVESLOPE_MAXSLOPE Ave Slope max slope
1604 DBDT_AVESLOPE_BACKSTEP Ave Slope back step
1700 DBDT_TRAPEZ_FILTERON Trapez Filter
1701 DBDT_TRAPEZ_SONDDIST 'Trapez Sounding Distance [s]'
1702 DBDT_TRAPEZ_GTIME1 Trapez Gate Time 1 [s]
1703 DBDT_TRAPEZ_GTIME2 Trapez Gate Time 2 [s]
1704 DBDT_TRAPEZ_GTIME3 Trapez Gate Time 3 [s]
1705 DBDT_TRAPEZ_WIDTH1 Trapez Width 1 [s]
1706 DBDT_TRAPEZ_WIDTH2  Trapez Width 2 [s]
1707 DBDT_TRAPEZ_WIDTH3 Trapez Width 3 [s]
1708 DBDT_TRAPEZ_SPIKEFACTOR Trapez Spike Factor
1709 DBDT_TRAPEZ_MINGATEPROCENT Trapez Min. No. Gates [%]
1710 DBDT_TRAPEZ_MINSONDGATES Trapez Min. No. Gates per Sounding